Low water pressure
Also called: low pressure, boiler pressure, bar, pressure gauge, water pressure, F1, F.22, E119, refill
Sort it soonWTF it means
The water pressure inside your heating system has dropped too low, so the boiler has stopped to protect itself. Normal is about 1–1.5 bar with the heating cold (rising to around 2 bar when hot); below roughly 0.5–0.8 bar most boilers give up.
What to do about it
Top it up with the filling loop: with the boiler off and cool, slowly open the filling-loop valve(s) under the boiler, watch the gauge rise to 1–1.5 bar, then close them firmly. Reset the boiler if it asks. Your manual shows where the loop (or filling key) is.
For the record
A pressure drop after bleeding radiators is normal: just top up. Topping up every week or two means there's a leak somewhere (check radiator valves and the pressure-relief pipe outside), so get an engineer. Common codes, as each brand has its own: Ideal F1, Vaillant F.22, Baxi E119.